GE Torque Chart

GE General Torque requirements for non-structural flanges
 
This is a general torque chart guide with GE values.  It is supplied only as a reference in the event you are without technical assistance from GE.  ALWAYS follow the jobsite or manufacturers recommendations and specifications.
 
 
Nominal Bolt Diameter & T.P.I. Head Marking 1 
Six Radial Lines
Ft. Lbs.
Head Marking 2 
L, CR, B7, HB7 
Ft. Lbs.
Head Marking 3 
A2A, A2B, B8M  
Ft. Lbs
 
  8 - 32   0.8 - 1   0.8 - 1   0.2 - 0.9
10 - 32   2 - 3   2 - 3   1.5 - 2
  1/4 - 20   5 - 6   5 - 6   4 - 5
5/16 - 18   9 - 11   9 - 11   8 - 10
  3/8 - 10   17 - 21   14 - 17   11 - 14
1/2 - 13   52 - 56   43 - 45   36 - 37
  5/8 - 11   98 - 105   81 - 85   68 - 69
3/4 - 10   161 - 178   134 - 144   111 - 117
  7/8 - 9   252 - 277   209 - 224   174 - 182
1 - 8   366 - 407   302 - 329   251 - 267
  1 1/8 - 8   532 - 606   438 - 490   362 - 397
1 1/4 - 8   699 - 804   573 - 650   472 - 527
  1 3/8 - 8   950 - 1102   778 - 891   640 - 722
1 1/2 - 8   1201 - 1400   982 - 1132   807 - 918
Head marking 1 material:  C1A3A,  C1A5
Head marking 2 material:  B50A125E, B5F5B3, C1A2A, C1A2B, C1A3A, C1A3B, C1A3C, C1A3D, C1A5CI, C1A5D1
Head marking 3 material:  C1F18A1, C1F19A1, C1F19A2, C2F9A, C2F10B

 


Home  |  School  |  MW to MW  |  The Network  |  Must Reads  |  The Store  |  Contact Us  |  Terms of Use  |  Privacy Policy  |  Site Map

MillwrightMasters.com is best viewed with Internet Explorer 6.0 or above.
External links are provided for reference purposes only.  MillwrightMasters.com is not responsible for the content of external internet sites.
© 2007-2010 MillwrightMasters.com  All rights reserved.


MillwrightMasters.com Fire Logo